Skip to main content Skip to search Skip to main navigation
►Contact us: (+49)40-23 78 53-0
►Smart choices. Trusted brands. Fair prices.
►Your trusted partner – for more than 40 years

Ledvance LED bulb DULUX LED SE9 AC V 4W 830 2G7

Product information "Ledvance LED bulb DULUX LED SE9 AC V 4W 830 2G7"

Product benefits: Operates directly from a 230 V mains supply. Not suitable for use with conventional ballasts (KVG/VVG). Not suitable for use with electronic ballasts (EVG). Easy to install. Low energy consumption. Easy lamp replacement thanks to compact design
Product features: LED replacement for conventional compact fluorescent lamps at mains voltage. Service life of up to 30,000 hours. Single-ended 4-pin 2G7 base. Protection class: IP20. Mercury-free lamps
Safety instructions: Not suitable for use with conventional ballasts. Not suitable for use with electronic ballasts. The operating temperature range of the DULUX LED is limited. If there is any doubt regarding the suitability of the application, please measure the Tc temperature on the product prior to installation. All electrical connections must only be carried out by qualified personnel. The lamp is not suitable for use in emergency lighting systems. Do not touch the lamp if it is damaged. Operation with a defective outer bulb is not permitted.
Electrical data: Rated power: 4 W, rated power: 4.00 W, rated voltage: 220–240 V, operating mode: mains voltage, power consumption of the conventional lamp: 9 W, rated current: 18 mA, current type: alternating current (AC), inrush current: 13 A, suitable for direct current operation: Yes, DC input voltage: 186–270 V, Operating frequency: 50/60 Hz, Mains frequency: 50/60 Hz, Max. number of lamps on B10 A circuit breaker: 46, Max. number of lamps on circuit breaker B16 A: 57, Harmonic content: ? 20 %, Mains power factor ?: > 0.90
Photometric data: Luminous flux: 500 lm, Luminous efficacy: 125 lm/W, Luminous flux maintenance at the end of rated life: 0.96, Light colour (designation): Warm white, colour temperature: 3000 K, colour rendering index Ra: 80, light colour: 830, standard deviation of colour matching: ?6 sdcm, Rated luminous flux maintenance factor at 6,000 h: 0.90, Flicker parameter (Pst LM): 1.0, Stroboscopic effect parameter (SVM): 0.4
Illumination data: Beam angle: 130°, Warm-up time (60 %): ‹ 0.50 s, Start-up time: < 0.5 s
Dimensions & weight: Overall length: 150.00 mm, Product weight: 40.00 g
Temperatures & operating conditions: Ambient temperature range: -20…+45 °C, Maximum temperature at measurement point tc: 82 °C
Service life: L70/B50 service life at 25 °C: 30,000 h, Number of switching cycles: 200,000, Luminous flux retention at end of service life: 0.96, Note: Lamp survival factor at 6,000 h: ? 0.90
Additional product data: Base (standard designation): 2G7, Mercury content of the lamp: 0.0 mg, Mercury-free: Yes, Design / finish: Matt, Product note: Available from December 2025
Applications: Dimmable: No
Certificates & Standards: Energy efficiency class: E, Energy consumption: 4.00 kWh/1,000 h, Ingress protection: IP20, Standards: CE, EAC, UKCA, Photobiological risk group according to EN62778: RG0
Country-specific information: Order number: DULUX LED S/E9
LOGISTICS DATA: Storage temperature range: -20…+80 °C
Data in accordance with the Energy Labelling Regulation EU 2019/2015: Lighting technology used: LED, Diffuse or directional light: NDLS, Mains voltage / Not directly connected to the mains: MLS, Light source cap (or other electrical interface): 2G7, Connected light source (CLS): No, Colour-tunable light source: No, Enclosure: No, Light source with high luminance: No, Anti-glare shield: No, Similar colour temperature: SINGLE_VALUE, Power consumption in standby mode: 0 W, Indication of equivalent power consumption: No, Length: 150.00 mm, Height: 20.8 mm, Width: 32 mm, Colour value component x: 0.434, Colour value component y: 0.403, R9 colour rendering index value: 1, Half-angle equivalent: SPHERE_360, service life factor: 0.90, displacement factor: 0.90, LED light source replaces a fluorescent light source: No, EPREL ID: 2416884, Model number: AC85412
PRODUCT DATA SHEET ON ENVIRONMENTAL PROPERTIES AND CHARACTERISTICS: Minimum proportion of recycled M

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


  • Length [mm]: 150
  • Width [mm]: 32
  • Height [mm]: 20.8
  • Energy efficiency class (EEC) on a scale of A (highest efficiency) to G (lowest efficiency): E
  • Energy Consumption [kWh/1000h]: 4
  • Luminous Flux [lm]: 500
  • Beam angle [°]: 130
  • Power [W]: 4
  • Colour Temperature [K]: 3000
  • Colour Temperature Range [K]: 3000
  • Avergae Lifetime [h]: 30000
  • Base: 2G7
  • IP Protection Class: IP20
  • CRI: 80
  • EPREL code: 2416884
  • Voltage [V]: 220-240
  • Dimmable: No
  • Short Description: DULUX LED S/E9 AC MAINS VALUE 4W 830 2G7
    Series: DULUX LED S/E AC MAINS VALUE
    EAN/GTIN: 4099854669873
  • Product Series: DULUX LED S/E AC MAINS VALUE
  • Light colour: 830
  • Herstellerangaben gemaess EU-Produktsicherheitsverordnung:
    LEDVANCE GmbH, Parkring 1-5, 85748 Garching b. München, DE, contact@ledvance.com
Skip product gallery

Produktserie

LED-Lampe DULUX LED SE9 AC V 4W 840 in Frontansicht
Energieeffizienzklasse D
Ledvance LED Lamp DULUX LED SE9 AC V 4W 840 2G7
OS-4099854669712

Product advantages: Operation directly at 230 V mains voltage. Not suitable for operation with conventional control gear (KVG/VVG). Not suitable for operation with electronic control gear (EVG). Easy installation. Low energy consumption. Easy lamp change thanks to compact designProduct properties: LED replacement for conventional compact fluorescent lamps at mains voltage. Service life up to 30,000 h. Single-sided 4-pin plug base 2G7. Degree of protection: IP20. Mercury-free lampsSafety instructions: Not suitable for operation with conventional control gear. Not suitable for operation with electronic control gear. The operating temperature range of the DULUX LED is limited. If there are doubts about the suitability of the application, please measure the Tc temperature at the product before installation. All electrical connections must only be carried out by qualified personnel. Lamp is not suitable for emergency lighting operation. Do not touch the lamp if it is damaged. Operation with defective outer bulb not permitted.Electrical data: Rated power: 4 W, Rated power: 4.00 W, Rated voltage: 220…240 V, Operating mode: Mains voltage, Power consumption of conventional lamp: 9 W, Rated current: 18 mA, Type of current: Alternating current (AC), Inrush current: 13 A, Suitable for DC operation: Yes, DC input voltage: 186…270 V, Operating frequency: 50/60 Hz, Mains frequency: 50/60 Hz, Max. Number of lamps on LS switch B10 A: 46, Max. Number of lamps on LS switch B16 A: 57, Harmonic content: ? 20 %, Power factor ?: > 0.90Photometric data: Luminous flux: 550 lm, Luminous efficacy: 135 lm/W, Luminous flux maintenance at the end of the rated service life: 0.96, Light color (designation): Cool white, Color temperature: 4000 K, Color rendering index Ra: 80, Light color: 840, Standard deviation of color matching: ?6 sdcm, Rated LLMF at 6,000 h: 0.90, Flicker measurement value (Pst LM): 1.0, Measurement value for stroboscopic effects (SVM): 0.4Lighting data: Radiation angle: 130 °, Warm-up time (60 %): ‹ 0.50 s, Start time: < 0.5 sDimensions & Weight: Overall length: 150.00 mm, Product weight: 40.00 gTemperatures & Operating Conditions: Ambient temperature range: -20…+45 °C, Maximum temperature at measuring point tc: 82 °CService life: Service life L70/B50 at 25 °C: 30000 h, Number of switching cycles: 200000, Luminous flux maintenance at the end of maintenance: 0.96, Rated lamp survival factor at 6,000 h: ? 0.90Additional product data: Base (standard designation): 2G7, Mercury content of the lamp: 0.0 mg, Mercury-free: Yes, Design / Version: Matt, Product note: Available from December 2025Application possibilities: Dimmable: NoCertificates & Standards: Energy efficiency class: D, Energy consumption: 4.00 kWh/1000h, Degree of protection: IP20, Standards: CE, EAC, UKCA, Photobiological risk group according to EN62778: RG0Country-specific information: Order number: DULUX LED S/E9LOGISTIC DATA: Storage temperature range: -20…+80 °CData according to the Regulation on energy consumption labeling EU 2019/2015: Lighting technology used: LED, Non-directional or directional light: NDLS, Mains voltage / Not directly connected to the mains voltage: MLS, Base of the light source (or other electrical interface): 2G7, Networked light source (CLS): No, Color-matched light source: No, Enclosure: No, Light source with high luminous density: No, Anti-glare shield: No, Similar color temperature: SINGLE_VALUE, Power consumption in standby mode: 0 W, Indication whether equivalent power consumption: No, Length: 150.00 mm, Height: 20.8 mm, Width: 32 mm, Color value component x: 0.382, Color value component y: 0.379, Value of the R9 color rendering index: 1, Half-angle correspondence: SPHERE_360, Service life factor: 0.90, Shift factor: 0.90, LED light source replaces a fluorescent light source: No, EPREL ID: 2416885, Model number: AC85413PRODUCT DATA SHEET ON ENVIRONMENTAL CHARACTERISTICS AND FEATURES: Minimum proportion of recycled m

● To be ordered
Regular price: €3.43
LED-Lampe DULUX LED SE9 AC V 4W 865 2G7 Frontansicht
Energieeffizienzklasse D
Ledvance LED bulb DULUX LED SE9 AC V 4W 865 2G7
OS-4099854669736

Product benefits: Operates directly from a 230 V mains supply. Not suitable for use with conventional ballasts (KVG/VVG). Not suitable for use with electronic ballasts (EVG). Easy to install. Low energy consumption. Easy lamp replacement thanks to compact designProduct features: LED replacement for conventional compact fluorescent lamps at mains voltage. Service life of up to 30,000 hours. Single-ended 4-pin 2G7 base. Protection class: IP20. Mercury-free lampsSafety instructions: Not suitable for use with conventional ballasts. Not suitable for use with electronic ballasts. The operating temperature range of the DULUX LED is limited. If there is any doubt regarding the suitability of the application, please measure the Tc temperature on the product prior to installation. All electrical connections must only be carried out by qualified personnel. The lamp is not suitable for use in emergency lighting systems. Do not touch the lamp if it is damaged. Operation with a defective outer bulb is not permitted.Electrical data: Rated power: 4 W, rated power: 4.00 W, rated voltage: 220–240 V, operating mode: mains voltage, power consumption of the conventional lamp: 9 W, rated current: 18 mA, current type: alternating current (AC), inrush current: 13 A, suitable for direct current operation: Yes, DC input voltage: 186–270 V, Operating frequency: 50/60 Hz, Mains frequency: 50/60 Hz, Max. number of lamps on B10 A circuit breaker: 46, Max. number of lamps on circuit breaker B16 A: 57, Harmonic content: ? 20 %, Mains power factor ?: > 0.90Photometric data: Luminous flux: 550 lm, Luminous efficacy: 135 lm/W, Luminous flux maintenance at the end of rated life: 0.96, Light colour (designation): Cool daylight, Colour temperature: 6500 K, Colour rendering index Ra: 80, colour rendering: 865, standard deviation of colour matching: ?6 sdcm, rated LLMF at 6,000 h: 0.90, flicker parameter (Pst LM): 1.0, Stroboscopic effect measurement (SVM): 0.4Photometric data: Beam angle: 130°, Warm-up time (60 %): ‹ 0.50 s, Start-up time: < 0.5 sDimensions & weight: Overall length: 150.00 mm, Product weight: 40.00 gTemperatures & operating conditions: Ambient temperature range: -20…+45 °C, Maximum temperature at measurement point tc: 82 °CService life: L70/B50 service life at 25 °C: 30,000 h, Number of switching cycles: 200,000, Luminous flux retention at end of service life: 0.96, Note: Lamp survival factor at 6,000 h: ? 0.90Additional product data: Base (standard designation): 2G7, Mercury content of the lamp: 0.0 mg, Mercury-free: Yes, Design / finish: Matt, Product note: Available from December 2025Applications: Dimmable: NoCertificates & Standards: Energy efficiency class: D, Energy consumption: 4.00 kWh/1,000 h, Protection rating: IP20, Standards: CE, EAC, UKCA, Photobiological risk group according to EN 62778: RG0Country-specific information: Order number: DULUX LED S/E9LOGISTICS DATA: Storage temperature range: -20…+80 °CData in accordance with the Energy Labelling Regulation EU 2019/2015: Lighting technology used: LED, Uncollimated or collimated light: NDLS, Mains voltage / Not directly connected to the mains voltage: MLS, Light source cap (or other electrical interface): 2G7, Networked light source (CLS): No, Colour-adjustable light source: No, Enclosure: No, High-luminance light source: No, Anti-glare shield: No, Similar colour temperature: SINGLE_VALUE, Power consumption in standby mode: 0 W, Indication of equivalent power consumption: No, Length: 150.00 mm, Height: 20.8 mm, Width: 32 mm, Colour value component x: 0.312, Colour value component y: 0.328, R9 colour rendering index value: 1, Half-angle equivalent: SPHERE_360, service life factor: 0.90, displacement factor: 0.90, LED light source replaces a fluorescent light source: No, EPREL ID: 2416886, Model number: AC85414PRODUCT DATA SHEET ON ENVIRONMENTAL PROPERTIES AND CHARACTERISTICS: Minimum proportion of recycled

● To be ordered
Regular price: €3.43
LED-Lampe DULUX LED SE11 AC V 6W 830 2G7 Frontansicht
Energieeffizienzklasse E
Ledvance LED Lamp DULUX LED SE11 AC V 6W 830 2G7
OS-4099854669750

Product advantages: Operation directly at 230 V mains voltage. Not suitable for operation with conventional control gear (KVG/VVG). Not suitable for operation with electronic control gear (EVG). Easy installation. Low energy consumption. Easy lamp replacement thanks to compact designProduct properties: LED replacement for conventional compact fluorescent lamps at mains voltage. Service life up to 30,000 h. Single-sided 4-pin plug base 2G7. Degree of protection: IP20. Mercury-free lampsSafety instructions: Not suitable for operation with conventional control gear. Not suitable for operation with electronic control gear. The operating temperature range of the DULUX LED is limited. If there are doubts about the suitability of the application, please measure the Tc temperature at the product before installation. All electrical connections must only be carried out by qualified personnel. Lamp is not suitable for emergency lighting operation. Do not touch the lamp if it is damaged. Operation with defective outer bulb not permitted.Electrical data: Rated power: 6 W, Rated power: 6.00 W, Rated voltage: 220…240 V, Operating mode: Mains voltage, Power consumption of conventional lamp: 11 W, Rated current: 28 mA, Type of current: Alternating current (AC), Inrush current: 19.6 A, Suitable for DC operation: Yes, DC input voltage: 186…270 V, Operating frequency: 50/60 Hz, Mains frequency: 50/60 Hz, Max. Number of lamps on LS switch B10 A: 30, Max. Number of lamps on LS switch B16 A: 38, Harmonic content: ? 20 %, Power factor ?: > 0.90Photometric data: Luminous flux: 700 lm, Luminous efficacy: 117 lm/W, Luminous flux maintenance at the end of the rated life: 0.96, Light color (designation): Warm white, Color temperature: 3000 K, Color rendering index Ra: 80, Light color: 830, Standard deviation of color matching: ?6 sdcm, Rated LLMF at 6,000 h: 0.90, Flicker measurement value (Pst LM): 1.0, Measurement value for stroboscopic effects (SVM): 0.4Lighting data: Radiation angle: 130 °, Warm-up time (60 %): ‹ 0.50 s, Start time: < 0.5 sDimensions & Weight: Overall length: 220.00 mm, Product weight: 50.00 gTemperatures & Operating Conditions: Ambient temperature range: -20…+45 °C, Maximum temperature at measuring point tc: 86 °CService life: Service life L70/B50 at 25 °C: 30000 h, Number of switching cycles: 200000, Luminous flux maintenance at the end of maintenance: 0.96, Rated lamp survival factor at 6,000 h: ? 0.90Additional product data: Base (standard designation): 2G7, Mercury content of the lamp: 0.0 mg, Mercury-free: Yes, Design / version: Matt, Product note: Available from December 2025Application possibilities: Dimmable: NoCertificates & Standards: Energy efficiency class: E, Energy consumption: 6.00 kWh/1000h, Degree of protection: IP20, Standards: CE, EAC, UKCA, Photobiological risk group according to EN62778: RG0Country-specific information: Order number: DULUX LED S/E11LOGISTIC DATA: Storage temperature range: -20…+80 °CData according to the Regulation on energy consumption labeling EU 2019/2015: Lighting technology used: LED, Unbundled or bundled light: NDLS, Mains voltage / Not directly connected to the mains voltage: MLS, Base of the light source (or other electrical interface): 2G7, Networked light source (CLS): No, Color-matched light source: No, Envelope: No, Light source with high luminous density: No, Anti-glare shield: No, Similar color temperature: SINGLE_VALUE, Power consumption in standby mode: 0 W, Indication of whether equivalent power consumption: No, Length: 220.00 mm, Height: 20.8 mm, Width: 32 mm, Color value component x: 0.434, Color value component y: 0.403, Value of the R9 color rendering index: 1, Half-angle correspondence: SPHERE_360, Service life factor: 0.90, Shift factor: 0.90, LED light source replaces a fluorescent light source: No, EPREL ID: 2416879, Model number: AC85415PRODUCT DATA SHEET ON ENVIRONMENTAL PROPERTIES AND CHARACTERISTICS: Minimum proportion of recycled

● ext. stock: 27 pcs.
Regular price: €3.96
LED-Lampe DULUX LED SE11 AC V 6W 840 2G7 Frontansicht
Energieeffizienzklasse E
Ledvance LED Lamp DULUX LED SE11 AC V 6W 840 2G7
OS-4099854669774

Product advantages: Operation directly at 230 V mains voltage. Not suitable for operation with conventional control gear (KVG/VVG). Not suitable for operation with electronic control gear (EVG). Easy installation. Low energy consumption. Easy lamp change thanks to compact designProduct properties: LED replacement for conventional compact fluorescent lamps at mains voltage. Service life up to 30,000 h. Single-sided 4-pin plug base 2G7. Degree of protection: IP20. Mercury-free lampsSafety instructions: Not suitable for operation with conventional control gear. Not suitable for operation with electronic control gear. The operating temperature range of the DULUX LED is limited. If there are doubts about the suitability of the application, please measure the Tc temperature at the product before installation. All electrical connections must only be carried out by qualified personnel. Lamp is not suitable for emergency lighting operation. Do not touch the lamp if it is damaged. Operation with defective outer bulb not permitted.Electrical data: Rated power: 6 W, Rated power: 6.00 W, Rated voltage: 220…240 V, Operating mode: Mains voltage, Power consumption of conventional lamp: 11 W, Rated current: 28 mA, Type of current: Alternating current (AC), Inrush current: 19.6 A, Suitable for DC operation: Yes, DC input voltage: 186…270 V, Operating frequency: 50/60 Hz, Mains frequency: 50/60 Hz, Max. Number of lamps on LS switch B10 A: 30, Max. Number of lamps on LS switch B16 A: 38, Harmonic content: ? 20 %, Power factor ?: > 0.90Photometric data: Luminous flux: 770 lm, Luminous efficacy: 128 lm/W, Luminous flux maintenance at the end of the rated life: 0.96, Light color (designation): Cool white, Color temperature: 4000 K, Color rendering index Ra: 80, Light color: 840, Standard deviation of color matching: ?6 sdcm, Rated LLMF at 6,000 h: 0.90, Flicker measurement value (Pst LM): 1.0, Measurement value for stroboscopic effects (SVM): 0.4Lighting data: Radiation angle: 130 °, Warm-up time (60 %): ‹ 0.50 s, Start time: < 0.5 sDimensions & Weight: Overall length: 220.00 mm, Product weight: 50.00 gTemperatures & Operating Conditions: Ambient temperature range: -20…+45 °C, Maximum temperature at measuring point tc: 86 °CService life: Service life L70/B50 at 25 °C: 30000 h, Number of switching cycles: 200000, Luminous flux maintenance at the end of maintenance: 0.96, Rated lamp survival factor at 6,000 h: ? 0.90Additional product data: Base (standard designation): 2G7, Mercury content of the lamp: 0.0 mg, Mercury-free: Yes, Design / Execution: Matt, Product note: Available from December 2025Application possibilities: Dimmable: NoCertificates & Standards: Energy efficiency class: E, Energy consumption: 6.00 kWh/1000h, Degree of protection: IP20, Standards: CE, EAC, UKCA, Photobiological risk group according to EN62778: RG0Country-specific information: Order number: DULUX LED S/E11LOGISTIC DATA: Storage temperature range: -20…+80 °CData according to the Regulation on energy consumption labeling EU 2019/2015: Lighting technology used: LED, Non-directional or directional light: NDLS, Mains voltage / Not directly connected to the mains voltage: MLS, Base of the light source (or other electrical interface): 2G7, Networked light source (CLS): No, Color-matched light source: No, Enclosure: No, Light source with high luminous density: No, Anti-glare shield: No, Similar color temperature: SINGLE_VALUE, Power consumption in standby mode: 0 W, Indication of whether equivalent power consumption: No, Length: 220.00 mm, Height: 20.8 mm, Width: 32 mm, Color value component x: 0.382, Color value component y: 0.379, Value of the R9 color rendering index: 1, Half-angle correspondence: SPHERE_360, Service life factor: 0.90, Shift factor: 0.90, LED light source replaces a fluorescent light source: No, EPREL ID: 2416881, Model number: AC85416PRODUCT DATA SHEET ON ENVIRONMENTAL CHARACTERISTICS AND FEATURES: Minimum proportion of recycled

● ext. stock: 14 pcs.
Regular price: €3.96
LED-Lampe DULUX LED SE11 AC V 6W 865 2G7 Frontansicht
Energieeffizienzklasse E
Ledvance LED Lamp DULUX LED SE11 AC V 6W 865 2G7
OS-4099854669798

Product advantages: Operation directly at 230 V mains voltage. Not suitable for operation with conventional control gear (KVG/VVG). Not suitable for operation with electronic control gear (EVG). Easy installation. Low energy consumption. Easy lamp change thanks to compact designProduct properties: LED replacement for conventional compact fluorescent lamps at mains voltage. Service life up to 30,000 h. Single-sided 4-pin plug base 2G7. Degree of protection: IP20. Mercury-free lampsSafety instructions: Not suitable for operation with conventional control gear. Not suitable for operation with electronic control gear. The operating temperature range of the DULUX LED is limited. If there are doubts about the suitability of the application, please measure the Tc temperature at the product before installation. All electrical connections must only be carried out by qualified personnel. Lamp is not suitable for emergency lighting operation. Do not touch the lamp if it is damaged. Operation with defective outer bulb not permitted.Electrical data: Rated power: 6 W, Rated power: 6.00 W, Rated voltage: 220…240 V, Operating mode: Mains voltage, Power consumption of conventional lamp: 11 W, Rated current: 28 mA, Type of current: Alternating current (AC), Inrush current: 19.6 A, Suitable for DC operation: Yes, DC input voltage: 186…270 V, Operating frequency: 50/60 Hz, Mains frequency: 50/60 Hz, Max. number of lamps on LS switch B10 A: 30, Max. number of lamps on LS switch B16 A: 38, Harmonic content: ? 20 %, Power factor ?: > 0.90Photometric data: Luminous flux: 770 lm, Luminous efficacy: 128 lm/W, Luminous flux maintenance at the end of the rated service life: 0.96, Light color (designation): Cool daylight, Color temperature: 6500 K, Color rendering index Ra: 80, Light color: 865, Standard deviation of color matching: ?6 sdcm, Rated LLMF at 6,000 h: 0.90, Flicker measurement value (Pst LM): 1.0, Measurement value for stroboscopic effects (SVM): 0.4Lighting data: Radiation angle: 130 °, Warm-up time (60 %): ‹ 0.50 s, Start time: < 0.5 sDimensions & Weight: Overall length: 220.00 mm, Product weight: 50.00 gTemperatures & Operating Conditions: Ambient temperature range: -20…+45 °C, Maximum temperature at measuring point tc: 86 °CService life: Service life L70/B50 at 25 °C: 30000 h, Number of switching cycles: 200000, Luminous flux maintenance at the end of maintenance: 0.96, Rated lamp survival factor at 6,000 h: ? 0.90Additional product data: Base (standard designation): 2G7, Mercury content of the lamp: 0.0 mg, Mercury-free: Yes, Design / version: Matt, Product note: Available from December 2025Application possibilities: Dimmable: NoCertificates & Standards: Energy efficiency class: E, Energy consumption: 6.00 kWh/1000h, Degree of protection: IP20, Standards: CE, EAC, UKCA, Photobiological risk group according to EN62778: RG0Country-specific information: Order number: DULUX LED S/E11LOGISTIC DATA: Storage temperature range: -20…+80 °CData according to the Regulation on energy consumption labeling EU 2019/2015: Lighting technology used: LED, Non-directional or directional light: NDLS, Mains voltage / Not directly connected to the mains voltage: MLS, Base of the light source (or other electrical interface): 2G7, Networked light source (CLS): No, Color-matched light source: No, Enclosure: No, Light source with high luminous density: No, Anti-glare shield: No, Similar color temperature: SINGLE_VALUE, Power consumption in standby mode: 0 W, Indication of whether equivalent power consumption: No, Length: 220.00 mm, Height: 20.8 mm, Width: 32 mm, Color value component x: 0.312, Color value component y: 0.328, Value of the R9 color rendering index: 1, Half-angle correspondence: SPHERE_360, Service life factor: 0.90, Displacement factor: 0.90, LED light source replaces a fluorescent light source: No, EPREL ID: 2416887, Model number: AC85417PRODUCT DATA SHEET ON ENVIRONMENTAL CHARACTERISTICS AND FEATURES: Minimum proportion of

● ext. stock: 6 pcs.
Regular price: €3.96
LED-Lampe DULUX LED SE7 AC V 3.5W 830 2G7 Frontansicht
Energieeffizienzklasse F
Ledvance LED Lamp DULUX LED SE7 AC V 3.5W 830 2G7
OS-4099854669811

Product advantages: Operation directly at 230 V mains voltage. Not suitable for operation with conventional control gear (KVG/VVG). Not suitable for operation with electronic control gear (EVG). Easy installation. Low energy consumption. Easy lamp replacement thanks to compact designProduct properties: LED replacement for conventional compact fluorescent lamps at mains voltage. Service life up to 30,000 h. Single-sided 4-pin plug base 2G7. Degree of protection: IP20. Mercury-free lampsSafety instructions: Not suitable for operation with conventional control gear. Not suitable for operation with electronic control gear. The operating temperature range of the DULUX LED is limited. If there are doubts about the suitability of the application, please measure the Tc temperature at the product before installation. All electrical connections must only be carried out by qualified personnel. Lamp is not suitable for emergency lighting operation. Do not touch the lamp if it is damaged. Operation with defective outer bulb not permitted.Electrical data: Rated power: 3.5 W, Rated power: 3.50 W, Rated voltage: 220…240 V, Operating mode: Mains voltage, Power consumption of conventional lamp: 7 W, Rated current: 16 mA, Type of current: Alternating current (AC), Inrush current: 11.2 A, Suitable for DC operation: Yes, DC input voltage: 186…270 V, Operating frequency: 50/60 Hz, Mains frequency: 50/60 Hz, Max. Number of lamps on LS switch B10 A: 53, Max. Number of lamps on LS switch B16 A: 67, Harmonic content: ? 20 %, Power factor ?: > 0.90Photometric data: Luminous flux: 360 lm, Luminous efficacy: 103 lm/W, Luminous flux maintenance at the end of the rated service life: 0.96, Light color (designation): Warm white, Color temperature: 3000 K, Color rendering index Ra: 80, Light color: 830, Standard deviation of color matching: ?6 sdcm, Rated LLMF at 6,000 h: 0.90, Flicker measurement value (Pst LM): 1.0, Measurement value for stroboscopic effects (SVM): 0.4Lighting data: Radiation angle: 130 °, Warm-up time (60 %): ‹ 0.50 s, Start time: < 0.5 sDimensions & Weight: Overall length: 120.00 mm, Product weight: 34.00 gTemperatures & Operating Conditions: Ambient temperature range: -20…+45 °C, Maximum temperature at measuring point tc: 82 °CService life: Service life L70/B50 at 25 °C: 30000 h, Number of switching cycles: 200000, Luminous flux maintenance at the end of maintenance: 0.96, Rated lamp survival factor at 6,000 h: ? 0.90Additional product data: Base (standard designation): 2G7, Mercury content of the lamp: 0.0 mg, Mercury-free: Yes, Design / Execution: Matt, Product note: Available from December 2025Application possibilities: Dimmable: NoCertificates & Standards: Energy efficiency class: F, Energy consumption: 4.00 kWh/1000h, Degree of protection: IP20, Standards: CE, EAC, UKCA, Photobiological risk group according to EN62778: RG0Country-specific information: Order number: DULUX LED S/E7LOGISTIC DATA: Storage temperature range: -20…+80 °CData according to the Regulation on energy consumption labeling EU 2019/2015: Lighting technology used: LED, Non-directional or directional light: NDLS, Mains voltage / Not directly connected to the mains voltage: MLS, Base of the light source (or other electrical interface): 2G7, Networked light source (CLS): No, Color-matched light source: No, Enclosure: No, Light source with high luminous density: No, Anti-glare shield: No, Similar color temperature: SINGLE_VALUE, Power consumption in standby mode: 0 W, Indication of whether equivalent power consumption: No, Length: 120.00 mm, Height: 20.8 mm, Width: 32 mm, Color value component x: 0.434, Color value component y: 0.403, Value of the R9 color rendering index: 1, Half-angle correspondence: SPHERE_360, Service life factor: 0.90, Shift factor: 0.90, LED light source replaces a fluorescent light source: No, EPREL ID: 2416880, Model number: AC85409PRODUCT DATA SHEET ON ENVIRONMENTAL CHARACTERISTICS AND FEATURES: Minimum proportion of recycled

● To be ordered
Regular price: €2.74
LED-Lampe DULUX LED SE7 AC V 3.5W 840 2G7 Frontansicht
Energieeffizienzklasse E
Ledvance LED Lamp DULUX LED SE7 AC V 3.5W 840 2G7
OS-4099854669835

Product advantages: Operation directly at 230 V mains voltage. Not suitable for operation with conventional control gear (KVG/VVG). Not suitable for operation with electronic control gear (EVG). Easy installation. Low energy consumption. Easy lamp change thanks to compact designProduct properties: LED replacement for conventional compact fluorescent lamps at mains voltage. Service life up to 30,000 h. Single-sided 4-pin plug base 2G7. Degree of protection: IP20. Mercury-free lampsSafety instructions: Not suitable for operation with conventional control gear. Not suitable for operation with electronic control gear. The operating temperature range of the DULUX LED is limited. If there are doubts about the suitability of the application, please measure the Tc temperature at the product before installation. All electrical connections must only be carried out by qualified personnel. Lamp is not suitable for emergency lighting operation. Do not touch the lamp if it is damaged. Operation with defective outer bulb not permitted.Electrical data: Rated power: 3.5 W, Rated power: 3.50 W, Rated voltage: 220…240 V, Operating mode: Mains voltage, Power consumption of conventional lamp: 7 W, Rated current: 16 mA, Type of current: Alternating current (AC), Inrush current: 11.2 A, Suitable for DC operation: Yes, Input voltage DC: 186…270 V, Operating frequency: 50/60 Hz, Mains frequency: 50/60 Hz, Max. Number of lamps on LS switch B10 A: 53, Max. Number of lamps on LS switch B16 A: 67, Harmonic content: ? 20 %, Power factor ?: > 0.90Photometric data: Luminous flux: 400 lm, Luminous efficacy: 114 lm/W, Luminous flux maintenance at the end of the rated life: 0.96, Light color (designation): Cool white, Color temperature: 4000 K, Color rendering index Ra: 80, Light color: 840, Standard deviation of color matching: ?6 sdcm, Rated LLMF at 6,000 h: 0.90, Flicker measurement value (Pst LM): 1.0, Measurement value for stroboscopic effects (SVM): 0.4Lighting data: Radiation angle: 130 °, Warm-up time (60 %): ‹ 0.50 s, Start time: < 0.5 sDimensions & Weight: Overall length: 120.00 mm, Product weight: 34.00 gTemperatures & Operating Conditions: Ambient temperature range: -20…+45 °C, Maximum temperature at measuring point tc: 82 °CService life: Service life L70/B50 at 25 °C: 30000 h, Number of switching cycles: 200000, Luminous flux maintenance at the end of maintenance: 0.96, Rated lamp survival factor at 6,000 h: ? 0.90Additional product data: Base (standard designation): 2G7, Mercury content of the lamp: 0.0 mg, Mercury-free: Yes, Design / version: Matt, Product note: Available from December 2025Application possibilities: Dimmable: NoCertificates & Standards: Energy efficiency class: E, Energy consumption: 4.00 kWh/1000h, Degree of protection: IP20, Standards: CE, EAC, UKCA, Photobiological risk group according to EN62778: RG0Country-specific information: Order number: DULUX LED S/E7LOGISTIC DATA: Storage temperature range: -20…+80 °CData according to the Regulation on energy consumption labeling EU 2019/2015: Lighting technology used: LED, Non-directional or directional light: NDLS, Mains voltage / Not directly connected to the mains voltage: MLS, Base of the light source (or other electrical interface): 2G7, Networked light source (CLS): No, Color-matched light source: No, Enclosure: No, Light source with high luminous density: No, Anti-glare shield: No, Similar color temperature: SINGLE_VALUE, Power consumption in standby mode: 0 W, Indication whether equivalent power consumption: No, Length: 120.00 mm, Height: 20.8 mm, Width: 32 mm, Color value component x: 0.382, Color value component y: 0.379, Value of the R9 color rendering index: 1, Half-angle correspondence: SPHERE_360, Service life factor: 0.90, Shift factor: 0.90, LED light source replaces a fluorescent light source: No, EPREL ID: 2416883, Model number: AC85410PRODUCT DATA SHEET ON ENVIRONMENTAL CHARACTERISTICS AND FEATURES: Minimum proportion of recycled

● ext. stock: 9 pcs.
Regular price: €2.74
LED-Lampe DULUX LED SE7 AC V 3.5W 865 2G7 Frontansicht
Energieeffizienzklasse E
Ledvance LED Lamp DULUX LED SE7 AC V 3.5W 865 2G7
OS-4099854669859

Product advantages: Operation directly at 230 V mains voltage. Not suitable for operation with conventional control gear (KVG/VVG). Not suitable for operation with electronic control gear (EVG). Easy installation. Low energy consumption. Easy lamp change thanks to compact designProduct properties: LED replacement for conventional compact fluorescent lamps at mains voltage. Service life up to 30,000 h. Single-sided 4-pin plug base 2G7. Degree of protection: IP20. Mercury-free lampsSafety instructions: Not suitable for operation with conventional control gear. Not suitable for operation with electronic control gear. The operating temperature range of the DULUX LED is limited. If there are doubts about the suitability of the application, please measure the Tc temperature at the product before installation. All electrical connections must only be carried out by qualified personnel. Lamp is not suitable for emergency lighting operation. Do not touch the lamp if it is damaged. Operation with defective outer bulb not permitted.Electrical data: Rated power: 3.5 W, Rated power: 3.50 W, Rated voltage: 220…240 V, Operating mode: Mains voltage, Power consumption of conventional lamp: 7 W, Rated current: 16 mA, Type of current: Alternating current (AC), Inrush current: 11.2 A, Suitable for DC operation: Yes, Input voltage DC: 186…270 V, Operating frequency: 50/60 Hz, Mains frequency: 50/60 Hz, Max. Number of lamps on LS switch B10 A: 53, Max. Number of lamps on LS switch B16 A: 67, Harmonic content: ? 20 %, Power factor ?: > 0.90Photometric data: Luminous flux: 400 lm, Luminous efficacy: 114 lm/W, Luminous flux maintenance at the end of the rated life: 0.96, Light color (designation): Cool daylight, Color temperature: 6500 K, Color rendering index Ra: 80, Light color: 865, Standard deviation of color matching: ?6 sdcm, Rated LLMF at 6,000 h: 0.90, Flicker measurement value (Pst LM): 1.0, Measurement value for stroboscopic effects (SVM): 0.4Lighting data: Radiation angle: 130 °, Warm-up time (60 %): ‹ 0.50 s, Start time: < 0.5 sDimensions & Weight: Overall length: 120.00 mm, Product weight: 34.00 gTemperatures & Operating Conditions: Ambient temperature range: -20…+45 °C, Maximum temperature at measuring point tc: 82 °CService life: Service life L70/B50 at 25 °C: 30000 h, Number of switching cycles: 200000, Luminous flux maintenance at the end of maintenance: 0.96, Rated lamp survival factor at 6,000 h: ? 0.90Additional product data: Base (standard designation): 2G7, Mercury content of the lamp: 0.0 mg, Mercury-free: Yes, Design / Version: Matt, Product note: Available from December 2025Application possibilities: Dimmable: NoCertificates & Standards: Energy efficiency class: E, Energy consumption: 4.00 kWh/1000h, Degree of protection: IP20, Standards: CE, EAC, UKCA, Photobiological risk group according to EN62778: RG0Country-specific information: Order number: DULUX LED S/E7LOGISTIC DATA: Storage temperature range: -20…+80 °CData according to the Regulation on energy consumption labeling EU 2019/2015: Lighting technology used: LED, Non-directional or directional light: NDLS, Mains voltage / Not directly connected to the mains voltage: MLS, Base of the light source (or other electrical interface): 2G7, Networked light source (CLS): No, Color-matched light source: No, Enclosure: No, Light source with high luminous density: No, Anti-glare shield: No, Similar color temperature: SINGLE_VALUE, Power consumption in standby mode: 0 W, Indication of whether equivalent power consumption: No, Length: 120.00 mm, Height: 20.8 mm, Width: 32 mm, Color value component x: 0.312, Color value component y: 0.328, Value of the R9 color rendering index: 1, Half-angle correspondence: SPHERE_360, Service life factor: 0.90, Shift factor: 0.90, LED light source replaces a fluorescent light source: No, EPREL ID: 2416882, Model number: AC85411PRODUCT DATA SHEET ON ENVIRONMENTAL CHARACTERISTICS AND FEATURES: Minimum proportion of

● To be ordered
Regular price: €2.74